AiroQue / Services / PFMEA Development
Service 03
PFMEA Development & Revision
A PFMEA is an argument about how your process can fail and what stops it. AiroQue builds that argument against your actual process, using your customer's rating scales and terminology — not a template with the part number changed.
1.0 Position
The difference between a filled-in form and an analysis
A PFMEA passes document review easily. Almost any spreadsheet with the right columns will. It fails a different test: whether the failure modes listed are ones your process can actually produce, and whether the controls listed are ones you actually run.
Generic PFMEAs are recognizable within a page. They contain failure modes for operations you do not perform, detection controls that describe an inspection nobody does at that frequency, and causes written at a level so general — “operator error”, “machine malfunction” — that no action could ever follow from them.
The logic AiroQue holds the document to
Every line is a chain, and the chain has to hold from end to end:
Function and requirement
What the operation is supposed to achieve, stated concretely enough that a failure of it can be described. Vague functions produce vague failure modes.
Failure mode
The specific way the operation fails to meet the requirement, in the language of the process: undersize, mislocated, missed operation, wrong material, incomplete cure, incorrect torque sequence.
Effect and severity
What that failure causes downstream, at the next operation, at final inspection, at your customer, and in service. Severity is driven by the worst credible effect, using the scale your customer or quality system defines.
Cause
Written at the level where a control could actually act — a specific fixture, setting, material condition or handling step, not a category.
Prevention and detection controls
Separated deliberately, because they are not equivalent. Prevention changes the odds that the cause occurs; detection only changes the odds that the result escapes. Documents that blur the two overstate how protected the process is.
Evaluation and action
Risk evaluated by the method your program uses, with recommended actions that name what changes in the process — not “monitor” or “emphasize during training”.
- Deliverable
- New or revised PFMEA covering the process scope agreed, with actions and alignment to the Control Plan
- Typical inputs
- Process Flow, drawing, routing, existing PFMEA, scrap and nonconformance history, customer rating tables
- Formats
- Your customer's form, your internal template, an AiroQue format, or a structure suited to your QMS software
- Starting price
- $1,500 — new development
$750 — revision of an existing document - Scales with
- Operation count, process complexity, condition of existing documentation, rating methodology
- Also covers
- Alignment with the Control Plan — see Service 04
- Revision support
- Change-driven and issue-driven revisions, per event or under a monthly agreement
Revision triggers
A PFMEA is a living document in principle and a stale one in practice. These events should force a revision:
- Engineering change affecting features, tolerances or materials
- Process, equipment, tooling or fixture change
- New operation, resequencing, or work moved outside
- Escape, customer complaint or corrective action
- Recurring scrap or rework not represented in the analysis
- New customer requirement or rating methodology
2.0 Scope
Development and revision work
Development from the process up
Built from the Process Flow, with functions, requirements, failure modes, effects, causes, controls, evaluation and actions established through review with your team rather than assumed.
- Manufacturing process risk analysis
- Failure-mode identification
- Failure-effect analysis
- Failure-cause analysis
- Prevention and detection controls
- Risk evaluation and recommended actions
Revision and rehabilitation
Many existing PFMEAs do not need replacing — they need the fiction removed and the real process put in. AiroQue reviews what you have, keeps what is valid, and reworks what is not.
- Reconciliation against the current routing
- Removal of failure modes the process cannot produce
- Correction of controls that do not match practice
- Incorporation of production issue history
- Process-control improvement recommendations
- Re-alignment with Process Flow and Control Plan
3.0 Tailoring
Methodology and format follow your program, not ours
Rating scales, structure and terminology vary by customer and by program. AiroQue applies what your requirements specify and keeps the analysis consistent with it throughout.
Built to your methodology
The value is in the thinking, not the form. Whatever structure your customer requires, the underlying analysis is the same — and AiroQue will produce it in that structure rather than converting a house format at the end.
Rating scales and evaluation method
Severity, occurrence and detection tables, and the risk evaluation method — RPN, action priority, criticality, or a customer-specific scheme — are applied exactly as your requirements define them. Supply the tables and they are the tables used.
Document structure
Traditional PFMEA worksheet, a structure-analysis and function-analysis based layout, or the specific form your customer mandates, including required header and approval fields.
Scope boundaries
Whole process, single operation, a family-level analysis with part-specific supplements, or a focused analysis on one problem area. Boundaries are agreed in writing before work starts.
Terminology
Failure modes and causes written using your plant's process vocabulary, so that operators and engineers recognize what is being described in their own words.
Linkage and cross-references
Row references, characteristic numbers and control references formatted so the PFMEA, Control Plan and inspection documentation can be read side by side.
Software and delivery
Excel, a customer-supplied form, PDF for release, or content prepared for entry into your quality software — with the revision block matching your document-control convention.
4.0 Adjacent services
Where the analysis goes next
Have a PFMEA you do not trust?
Send it with the current routing. AiroQue will tell you whether it needs a revision or a rebuild, and quote the work either way.